Mini50 Hz 1Φ – 230 V AC

Code Particular Type Capacitor 𝞵F Relay Amp HP
P01 Compass Panel Only Capacitor and MCB Protection 1 PHASE 36 𝞵F 8 Amp 0.50 HP
P02 45 𝞵F 10 Amp 1.00 HP

Mini50 Hz 1Φ – 230 V AC

Code Particular Type Start Capacitor Capacitor 𝞵F Relay Amp HP
P05 1-phase Control Panel
Content: Amp Meter, Volt Meter 2Pole Contactor, Capacitor Start & Run Capacitor, Over Load Protection switch Voltage range 160V to 240V
1 PHASE 80 TO 100V 𝞵F 36 𝞵F 4 TO 8 0.50 HP
P06 80 TO 100V 𝞵F 45 𝞵F 6 TO 10 0.75 HP
P07 80 TO 100V 𝞵F 45 𝞵F 6 TO 10 1.00 HP
P08 100 TO 120V 𝞵F 60 𝞵F 9 TO 14 1.50 HP
P09 100 TO 120V 𝞵F 72 𝞵F 10 TO 16 2.00 HP
P10 150 TO 200V 𝞵F 100 𝞵F 12 TO 21 3.00 HP

Mini50 Hz 1Φ – 230 V AC

Code Particular Type Start Capacitor Capacitor 𝞵F Relay Amp HP
P21 1phase Control Panel MK1 type Contactor Volt Meter, Amp Meter, Capacitor Start & Capacitor, Contactor with Thermistor Relay Voltage range 160V to 240V 1 PHASE 100 TO 120V 𝞵F 60 𝞵F 9 TO 14 1.50 HP
P22 100 TO 120V 𝞵F 72 𝞵F 10 TO 16 2.00 HP
P23 150 TO 200V 𝞵F 100 𝞵F 12 TO 21 3.00 HP
P24 180 TO 200V 𝞵F 120 𝞵F 22 TO 32 4.00 HP
P25 200 TO 250V 𝞵F 150 𝞵F 22 TO 32 5.00 HP

50 Hz 4Φ – 415 V AC

Code Particular Type Relay Amp HP
P31 3phase Control Panel MK1 type Contactor Volt Meter, Amp Meter, Contactor Relay 3Pole MCB, Auto Switch with SPP 3-PHASE DOL 1.5 A to 2.5 A 1.00 HP TP
P32 2.5 A to 4.0 A 2.00 HP TP
P33 4.0 A to 6.5 A 3.00 HP TP
P34 6 A to 10 A 4 & 5 HP TP
P35 9 A to 14 A 5 & 6 HP TP
P36 13 A to 21 A 7.5 HP TP
P40 3phase Control Panel MK1 type Volt Meter, Amp Meter Contactor Relay, 3Pole MCB, Single Phase preventer. Star Delta timer (3 to 30 sec.) 3-PHASE STAR/DELTA 6 A to 10 A 6.0 HP TP
P41 9 A to 14.0 A 7.5 HP TP
P42 13 A to 21 A 10 & 12.5 HP TP
P43 13 A to 21 A 15 HP TP
P44 20 A to 32 A 17.5 & 20HP TP

Solar Control Panels

  • Protection against: Dry running, Open circuit, Output short circuit, Reverse polarity and lightning
  • Features Maximum power point tracking (MPPT) and Surge protection
  • Soft start technology to prevent water hammering
  • In-built GSM based Remote monitoring system (RMS)
  • Higher wire to water efficiency
  • Plug and play technology resulting into hassle free installations
  • Easily reparable and replaceable parts
  • Can be easily switched to grid tied power source
  • Higher life expectancy and lower maintenance costs
  • Range from 1 H.P. / 0.75 K.W. to 10 H.P. / 7.5 K.W.